SDPOWR

Power Supply AC/DC 80Vdc-170Vdc

ELECTRICAL FEATURES
VersionSDPOWR.00SDPOWR.10
Power supply typeFull wave single phase rectifier AC/DC NOT ISOLATED and not stabilizedFull wave single phase rectifier AC/DC NOT ISOLATED and not stabilized + START UP circuit ( It is necessary with ISD)
Input power supply1) Direct connection with isolation transformer (700VA max) 1) Direct connection with isolation transformer (700VA max)
2) Indirect connection through soft-start power resistor, the maximum tolerable current at start-up on HV_IN and AUX_IN is 150A (no limit in the power of the transformer)2) Indirect connection through soft-start power resistor, the maximum tolerable current at start-up on HV_IN and AUX_IN is 150A (no limit in the power of the transformer)
INPUT FEATURES
VersionSDPOWR.00SDPOWR.10
Frequency50 ÷ 60Hz50 ÷ 60Hz
HV_IN (J8)55Vac ÷ 110Vac55Vac ÷ 110Vac
AUX_IN (J7)Up to 32VacUp to 27Vac
OUTPUT FEATURES
VersionSDPOWR.00SDPOWR.10
HV_OUT (J2-J4 )Up to 190Vdc, Inom=4A (VRipple=5V@4A, Tamb.=40 °C)Up to 190Vdc, Inom=4A (VRipple=5V@4A, Tamb.=40 °C)
Overload Imax=6A (5sec)Overload Imax=6A (5sec)
Capacitor on HV_OUT8800 μF8800 μF
AUX_OUT (J1)Up to 50Vdc, Inom=1A (VRipple=5V@1A)Up to 50Vdc, Inom=1A (VRipple=5V@1A)
Overload Imax=2A (5sec)Overload Imax=2A (5sec)
Overload protection on HV and AUX sectionsNONO
Over-temperature protection on HV and AUX sectionsNONO
Power supply internal configurationIMMAGINE DA INSERIRE (MANCA)IMMAGINE DA INSERIRE (MANCA)
Internal isolation HV – AUXYESNO
Internal referencesGND_HV isolated from GND_AUXGND_HV isolated from GND_AUX
LedHV_OUT (DL2), AUX_OUT (DL1), DUMP (DL3) interventionHV_OUT (DL2), AUX_OUT (DL1), DUMP (DL3) intervention
FUSES
VersionSDPOWR.00SDPOWR.10
On INPUTOn HV_IN (10A time-delay) and AUX_IN (10A time-delay)On HV_IN (10A time-delay) and AUX_IN (10A time-delay)
On OUTPUTOn HV_OUT (8A time-delay) and Rext. DUMPOn HV_OUT (8A time-delay) and Rext. DUMP
DUMP
VersionSDPOWR.00SDPOWR.10
Intervention typeIn case of overvoltage and for the discharge of the residual voltage on HV_OUTIn case of overvoltage and for the discharge of the residual voltage on HV_OUT
VDthr (Deactivation dump threshold)HV_OUT < 45VdcHV_OUT < 45Vdc
Internal resistance110Ω ³110Ω ³
External resistance (J6)≥ 56Ω≥ 56Ω
Dump disable input (J5)YesYes
ENVIRONMENTAL CONDITIONS
VersionSDPOWR.00SDPOWR.10
Operating environment temperaturefrom +5 to +40 °C from +5 to +40 °C
Relative humidityfrom 5% to 85% non-condensingfrom 5% to 85% non-condensing

Used with